Products Types Info
Type J Thermocouple

Temperature Range
32 to 1382°F (0 to 750°C)
Accuracy
•Standard Limits: ± 2.2°C or ± 0.75% Tol.
•Special Limits: ± 1.1°C or ± 0.4% Tol.
Type J thermocouples are suitable for use in vacuum, in oxidising and reducing atmospheres or inert gas atmospheres. They are used for temperature measurements 760°C and below.
Type K Thermocouple
Temperature Range
–328 to 2282°F (–200 to 1250°C)
Accuracy
•Standard Limits: ± 2.2°C or ± 0.75% Tol.
•Special Limits: ± 1.1°C or ± 0.4% Tol.
Type K Thermocouples are the most common calibration for providing the widest operating range. Recommended for continuous oxidizing or inert atmospheres. Most commonly used for temperatures above 538°C. Not suitable for sulfur environments.
Type T Thermocouple
Temperature Range
-454 to 700F(-270 to 370C)
Accuracy
• Standard Limits: ± 2.2°C or ± 0.75% Tol.
• Special Limits: ± 1.1°C or ± 0.4% Tol.
Suitable in oxidizing, reducing, or inert atmospheres as well as vaccuum. Moisture resistant and very stable. This type is best suited for low temperature service. Because of its stability at lower temperatures, this is a superior thermocouple for a wide variety of applications in low and cryogenic
4-Wire RTD
The optimum form of connection for RTDs is a four-wire circuit. It removes the error caused by mismatched resistance of the lead wires.
Platinum 100 RTD
The Pt1000 has 1000 ohms resistance at 0 C. These sensors are normally fitted into some type of protective sheath or mounting to form a probe.
Flanges
We are one of the leading manufacturers & exporters of threaded flanges, blind flanges, slip on flanges and more.
All
Products
[aws_search_form]
Suggestions:
What type of product are you looking for?
Some quick links to get you pointed in the right direction.
All
Products
[aws_search_form]
Industries We Serve
Aerospace
[/ult_content_box]Energy & Power
[/ult_content_box]Oil & Gas
[/ult_content_box]HVAC
[/ult_content_box]Popular Thermocouples
Popular RTDs
Popular Bearing Sensors
Popular Thermowells
Popular Products
Type J Thermocouple

Temperature Range
32 to 1382°F (0 to 750°C)
Accuracy
•Standard Limits: ± 2.2°C or ± 0.75% Tol.
•Special Limits: ± 1.1°C or ± 0.4% Tol.
Type J thermocouples are suitable for use in vacuum, in oxidising and reducing atmospheres or inert gas atmospheres. They are used for temperature measurements 760°C and below.
Type N Thermocouple
Temperature Range
–328 to 2282°F (–200 to 1250°C)
Accuracy
•Standard Limits: ± 2.2°C or ± 0.75% Tol.
•Special Limits: ± 1.1°C or ± 0.4% Tol.
Type K Thermocouples are the most common calibration for providing the widest operating range. Recommended for continuous oxidizing or inert atmospheres. Most commonly used for temperatures above 538°C. Not suitable for sulfur environments.
Type T Thermocouple
Temperature Range
-454 to 700F(-270 to 370C)
Accuracy
• Standard Limits: ± 2.2°C or ± 0.75% Tol.
• Special Limits: ± 1.1°C or ± 0.4% Tol.
Suitable in oxidizing, reducing, or inert atmospheres as well as vaccuum. Moisture resistant and very stable. This type is best suited for low temperature service. Because of its stability at lower temperatures, this is a superior thermocouple for a wide variety of applications in low and cryogenic
4-Wire RTD
The optimum form of connection for RTDs is a four-wire circuit. It removes the error caused by mismatched resistance of the lead wires.
Platinum 100 RTD
The Pt1000 has 1000 ohms resistance at 0 C. These sensors are normally fitted into some type of protective sheath or mounting to form a probe.
Flanges
We are one of the leading manufacturers & exporters of threaded flanges, blind flanges, slip on flanges and more.